Need help finding us? Learn More
New Zealand
Auckland | Christchurch
Tel: 0800 688 700
Queensland
Unit 2/11-15 Baylink Avenue, Deception Bay, QLD, 4508
Click & Collect
Victoria
5 Barrie Rd, Tullamarine VIC 3043
Click & Collect, 3-4 days
GO x Colourworld Geelong: 38-40 Cheetham Rd, Moolap VIC 3224
Click & Collect within 3-4 days
South Australia
30-32 Shipwright Rd, Largs North, SA, 5016
Click & Collect within 3-4 days
New South Wales
21 Chifley Street, Smithfield, NSW, 2164
Click & Collect within 3-4 days
Western Australia
15 Crompton Rd, Rockingham, WA, 6168
Click & Collect within 5+ days




We’re here to help
Equipment specialists ready to go above and beyond. Expert advice, 1:1 support and care that you’d expect from a premium brand.
Message a Specialist SALES@GOIND.CO.NZEnquire For Price
Contact form

Fluids
> Suitable for Diesel, AdBlue, Water, Lube Oil, Grey Water
> NOT Suitable for use with Petrol / Flammable Liquids
Features
> Made in UK quality
> Commonly used to control the level of diesel fuel in generator day tanks.
> Four inputs used for pump control and fail safe.
> Low level input starts the pump and will keep the pump running until the high level input is triggered.
> In the event that pump fails to start the low low level input will trigger the audible alarm and will signal a BMS system if connected.
> In the event that pump fails to stop the high high level input will trigger the audible alarm and will signal a BMS system if connected.
> Pump relay is 240V, 6 A rated.
> LED indicators change colour to indicate status of system.
> Power supply 240V
> Uses up to 4 float switches, not provided, which come with a 1” BSPT male tank fitting.
> Can be connected to an OLE C2020 or T5020 tank gauge which must have relay boards fitted.
> Maximum tank height 4m.
> The enclosures are IP65 rated and are suitable for outdoor use.
> can be used for hazardous area installation if suitable barriers are incorporated into the switch input circuits.
> Inputs can be from cabled float switches or from rigid multi float probes.
> Pump Control is achieved by jumper selection to latch the pump connection output between Low and High. This results in a simple day tank controller. There is a High High Fail safe circuit available. One Unit does it all.
Note: When used in Pump Control mode, there is no Volt Free Contact for the 2nd and 3rd Output circuit. This mode uses the Pump Output circuit. (See wiring diagrams in Document Download section.
Examples of Use
> Tank systems requiring up to 4 Switch and Alarm Channels in one easy to configure unit.
> High High, Low,Low Low, and Bund - 3 x Level Alarms and 1 x Bund, all volt free out.
> High High, High, Low, Low Low - 4 x Level Alarms and Volt free out
> High High, Pump Stop, Pump Start, Low Low - Control Filling a Generator Day Tank
> High High, Pump Start, Pump Stop, Low Low - Empty a Sump or Waste Oil / Coolant Tank
FAQ
Q/ Can this be used to control filling a tank as well as emptying one
A/ Yes. The system can be set for either way round, and has an emergency automatic shut down when High Level is reached on Tank Filling applications
Q/ Can we use any type of level switch input.
A/ Yes, if the switches are "simple apparatus" meaning reed switch or similar . (Not capacitance or resistance)
Q/ Can the system power a pump directly.
A/ No. The T4000 is a switch to operate the power to a pump. You may need to include a contactor in the circuit if the load is more than 6 to 8 amps.
Other payment options
Couldn't load pickup availability
The Basics
At a Glance
The OLE T4000-240PR Day Tank Controller is a cost effective yet reliable instrument commonly used to control the operation of Generator Day Tanks. The T4000-240PR is suitable for use with Diesel. Four Inputs are used for pump control and fail safe. The four inputs are commonly set at Low Low / Low / High / High High.
The Low level input starts the pump and will keep the pump running until the high level input is triggered. In the event that the pump fails to start the low low level input will attempt to stop the pump, it will trigger the audible alarm and will signal a BMS system if connected.
Conversely in the event that the pump fails to stop the high high level input will attempt to stop the pump, it will trigger an audible alarm and will signal also a BMS if connected.
Up to 4 OLE B8 Float Switches are required for use with the OLE T4000-240PR Day Tank Controller. These are purchased separately allowing for customisation of the application of this innovative instrument.
Fluids
> Suitable for Diesel, AdBlue, Water, Lube Oil, Grey Water
> NOT Suitable for use with Petrol / Flammable Liquids
Features
> Made in UK quality
> Commonly used to control the level of diesel fuel in generator day tanks.
> Four inputs used for pump control and fail safe.
> Low level input starts the pump and will keep the pump running until the high level input is triggered.
> In the event that pump fails to start the low low level input will trigger the audible alarm and will signal a BMS system if connected.
> In the event that pump fails to stop the high high level input will trigger the audible alarm and will signal a BMS system if connected.
> Pump relay is 240V, 6 A rated.
> LED indicators change colour to indicate status of system.
> Power supply 240V
> Uses up to 4 float switches, not provided, which come with a 1” BSPT male tank fitting.
> Can be connected to an OLE C2020 or T5020 tank gauge which must have relay boards fitted.
> Maximum tank height 4m.
> The enclosures are IP65 rated and are suitable for outdoor use.
> can be used for hazardous area installation if suitable barriers are incorporated into the switch input circuits.
> Inputs can be from cabled float switches or from rigid multi float probes.
> Pump Control is achieved by jumper selection to latch the pump connection output between Low and High. This results in a simple day tank controller. There is a High High Fail safe circuit available. One Unit does it all.
Note: When used in Pump Control mode, there is no Volt Free Contact for the 2nd and 3rd Output circuit. This mode uses the Pump Output circuit. (See wiring diagrams in Document Download section.
Examples of Use
> Tank systems requiring up to 4 Switch and Alarm Channels in one easy to configure unit.
> High High, Low,Low Low, and Bund - 3 x Level Alarms and 1 x Bund, all volt free out.
> High High, High, Low, Low Low - 4 x Level Alarms and Volt free out
> High High, Pump Stop, Pump Start, Low Low - Control Filling a Generator Day Tank
> High High, Pump Start, Pump Stop, Low Low - Empty a Sump or Waste Oil / Coolant Tank
FAQ
Q/ Can this be used to control filling a tank as well as emptying one
A/ Yes. The system can be set for either way round, and has an emergency automatic shut down when High Level is reached on Tank Filling applications
Q/ Can we use any type of level switch input.
A/ Yes, if the switches are "simple apparatus" meaning reed switch or similar . (Not capacitance or resistance)
Q/ Can the system power a pump directly.
A/ No. The T4000 is a switch to operate the power to a pump. You may need to include a contactor in the circuit if the load is more than 6 to 8 amps.

-
pagination here
Recently Viewed Products
-
LG Linda G
One of the nicest and friendliest companies I have had the pleasure to deal with. Helpful beyond words in regards to what air sprayer to buy for hubby for a surprise. They explained options and advised what machine to get for the purpose we needed it for. Their shipping was super fast and I have no hesitation at all in recommending them.
Customer service is pretty slack in companies now but, you guys exemplify what good old customer service used to be - THANK YOU!!!! -
TC Todd Cox
I purchased a Mirka Derios Sander and extractor setup fro Go Industrial. The customer service was excellent and the salesman knew the products well. I have since used the Mirka sander and extractor and this piece of kit is amazing.
Zero dust particles escaped the vacuum extraction and the finish with the abrasive pads is amazing. I would definitely recommend Go industrial for any products that is needed and I know I will be returning there in the future for more purchases.
Great work Go Industrial team.
-
SP Shane Parry
Magnificent all round. Great service and great equipment. Cannot recommend these guys enough. Bloody legends check them out!!!!
-
JB John Bromhead
An absolutely impeccable process, from ordering, to the super fast delivery, the the top quality of the product.
In 23yrs in the building, I have never dealt with a better, more efficient and knowledgeable rep in Jacob. His knowledge and ease of transitions the order is second to none! -
KR Kevin Reeve
Exceptional service and the videos they produce are great for a rookie like me. Responded to email for help within minutes.
I wish all companies were like these guys!
- Choosing a selection results in a full page refresh.
- Opens in a new window.